Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Pract Lab Med ; 38: e00354, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38283321

RESUMO

Objectives: Soluble B-Cell Maturation Antigen (sBCMA) is a degradation product of plasma cell-bound BCMA found in serum. Serum sBCMA concentrations correlate with bone marrow plasma cellularity, making it an attractive biomarker for monitoring plasma cell disorders, such as multiple myeloma. Here we evaluated the automated BCMA immunoassay for the ProteinSimple ELLA, for the analysis of sBCMA. Design & methods: Inter and intra-run precision was assessed through replicate sBCMA measurements at 3 different concentration levels. Linearity was determined through serial dilution of a high sBMCA patient sample. Accuracy was assessed through split specimen analysis on two separate lots of reagents. Stability was assessed at 3 temperature levels over 14 days. Cross-reactivity was assessed on BCMA targeting and non-targeting chemotherapeutics. A reference range was established through the analysis of 146 healthy donor samples. The effect of endogenous interferents was assessed through spiking and recovery studies. Results: Inter and intra-run precision studies afforded CVs of <10% at all three concentration levels. Analytical measurement range was confirmed from 0.1 to 7 ng/mL. Accuracy studies afforded a slope of 0.976, intercept of 1.22, R2 of 0.996. Assayed sBCMA values were unaffected by endogenous interferents and non-BMCA targeting antibodies. BCMA targeting therapeutics negatively affected assayed sBCMA concentrations. The reference range was established at 19-58 ng/mL sBCMA is analytically stable. Conclusions: The ProteinSimple ELLA sBCMA assay shows acceptable performance for the clinical assessment of sBCMA. The assay was highly affected by BCMA targeting therapeutics, thereby patients undergoing this therapy should not have their sBCMA levels assessed by this method.

3.
mSphere ; 7(4): e0019322, 2022 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-35703544

RESUMO

In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies" (https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serological-sciences-network). SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology standard reference material and first WHO international standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. SeroNet institutions reported development of a total of 27 enzyme-linked immunosorbent assay (ELISA) methods, 13 multiplex assays, and 9 neutralization assays and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. In conclusion, SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons. IMPORTANCE SeroNet institutions have developed or implemented 61 diverse COVID-19 serological assays and are collaboratively working to harmonize these assays using reference materials to establish standardized reporting units. This will facilitate clinical interpretation of serology results and cross-comparison of research data.


Assuntos
COVID-19 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , SARS-CoV-2 , Testes Sorológicos/métodos
4.
medRxiv ; 2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35262095

RESUMO

Background: In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies." SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. Methods: To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. Results: SeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. Conclusions: SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.

5.
Pediatr Infect Dis J ; 41(4): 302-303, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34803136

RESUMO

A child with chronic granulomatous disease on vancomycin treatment had V trough levels that became undetectable, as measured in our hospital's clinical laboratory by a commonly employed particle-enhanced turbidometric inhibition assay. An alternative laboratory method yielded appropriate results. Recognizing and resolving erroneously low V trough levels could prevent needless adjustments in dosing that could increase risk for acute kidney injury.


Assuntos
Injúria Renal Aguda , Doença Granulomatosa Crônica , Antibacterianos/uso terapêutico , Criança , Feminino , Doença Granulomatosa Crônica/complicações , Doença Granulomatosa Crônica/tratamento farmacológico , Humanos , Masculino , Estudos Retrospectivos , Vancomicina/uso terapêutico
6.
Thyroid ; 31(8): 1160-1170, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34042535

RESUMO

Background: Biotin has been reported to interfere with several commonly used laboratory assays resulting in misleading values and possible erroneous diagnosis and treatment. This report describes a prospective study of possible biotin interference in thyroid-related laboratory assays, with a comparison of different commonly used assay platforms. Materials and Methods: Thirteen adult subjects (mean age 45 ± 13 years old) were administered biotin 10 mg/day for eight days. Blood specimens were collected at three time points on day 1 and on day 8 (baseline, two, and five hours after biotin ingestion). Thyrotropin (TSH), free triiodothyronine (fT3), free thyroxine (fT4), total triiodothyronine (TT3), total thyroxine (TT4), thyroxine binding globulin (TBG), and thyroglobulin (Tg) levels were analyzed with four different platforms: Abbott Architect, Roche Cobas 6000, Siemens IMMULITE 2000, and liquid chromatography with tandem mass spectrometry (LC-MS/MS). TSH, fT3, fT4, TT3, and TT4 were measured with Abbott Architect and Roche Cobas 6000. fT3, fT4, TT3, and TT4 were also measured by LC-MS/MS. Tg was measured by Siemens IMMULITE 2000. TBG was assessed with Siemens IMMULITE 2000. Results: Significant changes in TSH, fT4, and TT3 measurements were observed after biotin exposure when the Roche Cobas 6000 platform was used. Biotin intake resulted in a falsely lower Tg level when measurements were performed with Siemens IMMULITE 2000. At the time points examined, maximal biotin interference was observed two hours after biotin exposure both on day 1 and day 8. Conclusions: A daily dose of 10 mg was shown to interfere with specific assays for TSH, fT4, TT3, and Tg. Physicians must be aware of the potential risk of erroneous test results in subjects taking biotin supplements. Altered test results for TSH and Tg can be particularly problematic in patients requiring careful titration of levothyroxine therapy such as those with thyroid cancer.


Assuntos
Biotina/análise , Biotina/farmacologia , Tireoglobulina/análise , Hormônios Tireóideos/análise , Tireotropina/análise , Adulto , Idoso , Cromatografia Líquida de Alta Pressão , Reações Falso-Negativas , Feminino , Humanos , Masculino , Espectrometria de Massas , Pessoa de Meia-Idade , Estudos Prospectivos , Testes de Função Tireóidea
7.
Nat Med ; 26(10): 1636-1643, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32839624

RESUMO

Several studies have revealed that the hyper-inflammatory response induced by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a major cause of disease severity and death. However, predictive biomarkers of pathogenic inflammation to help guide targetable immune pathways are critically lacking. We implemented a rapid multiplex cytokine assay to measure serum interleukin (IL)-6, IL-8, tumor necrosis factor (TNF)-α and IL-1ß in hospitalized patients with coronavirus disease 2019 (COVID-19) upon admission to the Mount Sinai Health System in New York. Patients (n = 1,484) were followed up to 41 d after admission (median, 8 d), and clinical information, laboratory test results and patient outcomes were collected. We found that high serum IL-6, IL-8 and TNF-α levels at the time of hospitalization were strong and independent predictors of patient survival (P < 0.0001, P = 0.0205 and P = 0.0140, respectively). Notably, when adjusting for disease severity, common laboratory inflammation markers, hypoxia and other vitals, demographics, and a range of comorbidities, IL-6 and TNF-α serum levels remained independent and significant predictors of disease severity and death. These findings were validated in a second cohort of patients (n = 231). We propose that serum IL-6 and TNF-α levels should be considered in the management and treatment of patients with COVID-19 to stratify prospective clinical trials, guide resource allocation and inform therapeutic options.


Assuntos
Infecções por Coronavirus/imunologia , Interleucina-1beta/imunologia , Interleucina-6/imunologia , Interleucina-8/imunologia , Pneumonia Viral/imunologia , Fator de Necrose Tumoral alfa/imunologia , Idoso , Betacoronavirus , COVID-19 , Infecções por Coronavirus/mortalidade , Infecções por Coronavirus/fisiopatologia , Infecções por Coronavirus/terapia , Citocinas/imunologia , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/mortalidade , Pneumonia Viral/fisiopatologia , Pneumonia Viral/terapia , SARS-CoV-2 , Índice de Gravidade de Doença , Taxa de Sobrevida
8.
Clin Biochem ; 50(15): 886-888, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28478046

RESUMO

OBJECTIVES: Chyluria is a medical condition with presence of chyle in urine. The disease is most prevalent in South East Asian countries mostly caused by parasitic (Wuchereria bancrofti) infections. Our objective was to investigate the spontaneous remission of non-parasitic chyluria. DESIGN AND METHODS: The spontaneous remission of non-parasitic chyluria cases were worked up with diagnostic investigations, clinical assessment and studied in detail with respect to their natural evolution. RESULTS: We present two patients who were evaluated in the nephrology clinic with symptoms of milky urine and painless hematuria. Midnight blood smear was negative for filarial parasites. Urine culture was without mycobacteria. Urine cytology and IgG western blot for cysticercus were negative. Imaging for a lymphatic leak by lymphoscintigraphy was unrevealing. Chyluria resolved spontaneously in both patients. CONCLUSIONS: In our cases, radiologic visualization via lymphoscintigraphy was unrevealing. The patients were managed conservatively and fortunately underwent spontaneous remission marked by the disappearance of chyluria within several months of her initial diagnosis. In our opinion this spontaneous remission could be due to unrevealed lymphatico-renal fistula collapse or sclerosis of lymphatics caused by contrast media.


Assuntos
Quilo , Remissão Espontânea , Idoso , Animais , Filariose Linfática/diagnóstico por imagem , Filariose Linfática/urina , Feminino , Humanos , Urina , Wuchereria bancrofti
9.
Clin Chim Acta ; 441: 90-1, 2015 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-25542530

RESUMO

BACKGROUND: D-lactic acidosis, also referred as D-lactate encephalopathy, has been reported in patients with short bowl syndrome (SBS). CASE REPORT: The neurologic symptoms include altered mental status, slurred speech, and ataxia. Onset of neurological symptoms is accompanied by metabolic acidosis and high anion gap. We present here a case of D-lactic acidosis in a patient with acute lymphoblastic leukemia (ALL) who developed severe neurological symptoms and metabolic acidosis due to vancomycin-resistant enterococci (VRE) infection, and elevated D-lactic acid.


Assuntos
Acidose Láctica/diagnóstico , Encefalopatias/diagnóstico , Leucemia-Linfoma Linfoblástico de Células Precursoras/diagnóstico , Acidose Láctica/sangue , Acidose Láctica/metabolismo , Idoso , Encefalopatias/sangue , Encefalopatias/metabolismo , Feminino , Humanos , Leucemia-Linfoma Linfoblástico de Células Precursoras/sangue , Leucemia-Linfoma Linfoblástico de Células Precursoras/metabolismo
10.
Ther Drug Monit ; 29(5): 632-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17898655

RESUMO

Caffeine is widely used in children's hospitals to treat neonatal apnea. Amikacin is used for treating hospital-acquired infections caused by Gram-negative bacteria resistant to other aminoglycosides. The blood levels, however, have to be monitored carefully because of its ototoxicity and nephrotoxicity. Methotrexate (MTX) is used as a chemotherapeutic agent in the treatment of leukemia and lymphoma as well as of certain solid tumors. Current enzyme multiplied immunoassay technique (EMIT) assays for caffeine, amikacin, and MTX lack low-end precision. In addition, the EMIT assays for MTX lack the sensitivity of reliable quantification to 0.05 micromol/L needed because of today's more rigorous requirements. The goal of the present study was to optimize the EMIT method parameters on the Dimension RxL Max, thereby providing applications with improved precision for all the three analytes and enhancing the sensitivity of the EMIT methotrexate assay. Serum samples were measured for caffeine, amikacin, and MTX by EMIT on the Dimension RxL Max and by EMIT (on the Olympus AU 600 for caffeine) and fluorescence polarization immunoassay [for MTX and amikacin (FPIA; TDx FLx)] at Quest Diagnostics. The new instrument method parameters that use larger sample volumes and longer observation of optical density changes (caffeine, MTX) provide improved sensitivity for MTX permitting reliable measurement at 0.05 micromol/L and improved precision for all three analytes. Within- and between-day imprecision were less than 6% for low to high concentrations of caffeine and amikacin controls and are less than 7.5% for MTX concentrations greater than 0.3 micromol/L and 12.3% at 0.06 micromol/L. The correlation coefficients for caffeine, amikacin, and MTX plotted for the Dimension RxL Max versus the methods used at Quest Diagnostics were 0.973, 0.986, and 0.992, respectively. These EMIT method applications now compare well with other established assays. The new Dimension RxL Max method parameters provide greatly improved precision and also meet today's clinical sensitivity guidelines (0.05 micromol/L) for MTX.


Assuntos
Monitoramento de Medicamentos/métodos , Ensaio de Imunoadsorção Enzimática/instrumentação , Amicacina/sangue , Amicacina/farmacocinética , Antibacterianos/sangue , Antibacterianos/farmacocinética , Antimetabólitos Antineoplásicos/sangue , Antimetabólitos Antineoplásicos/farmacocinética , Cafeína/sangue , Cafeína/farmacocinética , Estimulantes do Sistema Nervoso Central/sangue , Estimulantes do Sistema Nervoso Central/farmacocinética , Humanos , Metotrexato/sangue , Metotrexato/farmacocinética , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA